cover it

MTT Reflective Aluminized Surface Bonded to Insulating Fiberglass Thermal Tube Shield MTT - Chemical Resistance Index Aromatic Solvents Aliphatic Solvents Chlorinated Solvents Weak Bases Salts Strong Bases Salt Water 0-S-1926 Hydraulic Fluid MIL-H-5606 5 Severely Affected 4 More Affected 3 Affected Little Effect No Effect 2 1 Lube Oil MIL-L-7808 De-Icing Fluid MIL-A-8243 Strong Acids Strong Oxidants Esters/Ketones UV Light Petroleum Fungus ASTM G-21 5 Severely Affected 4 More Affected 3 Affected Little Effect No Effect 2 1 • Abrasion resistance: Very high • Abrasion test machine: Taber 5150 • Abrasion test wheel: Calibrase H-18 • Abrasion test load: 500g • Room temperature: 73 • Humidity: 55% • Foil layer worn through: 1,000 test cycles • Fiberglass layer worn through m test cycles P• re-test weight: P• ost-test weight: T• est end loss of mass point of destruction: °F aterial destroyed: 1,200 10,925.0 mg 9,607.6 mg 1,317.4 mg • Monofilament diameter: N/A • Flammability rating: Non Combustible • Recommended cutting: Scissor • Colours: 1 • Wall thickness: .025 Abrasion Test Data Physical Properties