cover it

SS MFI.00 00 03.12.13 MFI Resists Heat, Abrasion & Moisture Silicone Jacketed Fiberglass • Abrasion resistance: • Abrasion test machine: Taber 5150 • Abrasion test wheel: Calibrase H-18 • Abrasion test load: 500g • Room temperature: 71 • Humidity: 61% • P• re-test weight: P• ost-test weight: T• est end loss of mass point of destruction: Extremely High Small hole in coating: 400 Test Cycles • Several small holes worn through coating: 1,200 Test Cycles • Coating worn through, no wear on fiberglass: 4,800 T. Cycles • Fiberglass begins to show moderate wear: 6,500 Test Cycles • Material destroyed: 8,400 Test Cycles °F 22,961.3 mg mg 2,019.1 mg 20,942.2 • Monofilament diameter: N/A • Flammability rating a ASTM D-204: Non-Flasmmable • Recommended cutting: Scissor • Colours: 2 (RD) red / (BK) black • Wall thickness: .072 MFI - Chemical Resistance Index Aromatic Solvents Aliphatic Solvents Chlorinated Solvents Weak Bases Salts Strong Bases Salt Water 0-S-1926 Hydraulic Fluid MIL-H-5606 5 Severely Affected 4 More Affected 3 Affected Little Effect No Effect 2 1 Lube Oil MIL-L-7808 De-Icing Fluid MIL-A-8243 Strong Acids Strong Oxidants Esters/Ketones UV Light Petroleum Fungus ASTM G-21 5 Severely Affected 4 More Affected 3 Affected Little Effect No Effect 2 1 Abrasion Test Data Physical Properties

RkJQdWJsaXNoZXIy NTEwMDc=